Schematic changes on 12/18/2009 to deal with increased power needs of the DCM. FEB Card - changed 3.3V trace width specification to 4A (~1 sec fuse blow) - changed 24V trace width specification to 2A (~1 sec fuse blow) Indicator Card - changed 3.3V trace width specification to 0.2A (~1 sec fuse blow) - changed 24V trace width specification to 0.2A (~1 sec fuse blow) Backplane - changed 3.3V trace width specification to 16A (4A * 4) - changed 24V trace width specification to 8A (2A * 4) - changed 24V DCM trace width specification to 11A DCM Card - changed 3.3V trace width specification to 4A (~1 sec fuse blow) - changed 24V trace width specification to 2A (~1 sec fuse blow) - changed 24V DCM fuse to 6.3A - changed 24V DCM trace width specification to 11A (~1 sec fuse blow) - changed toggle switch to one that can handle up tp 7.5A @ 28VDC